Üdvözöljük a Mediso-nál

Válasszon régiót:

Észak-Amerika
Európa

Válasszon nyelvet:

Mehet

AnyScan® TRIO SPECT/CT

The only triple-detector SPECT/CT for high-end diagnostic and theranostic clinical and research applications

The triple-detector technology revolutionizes nuclear medicine with high accuracy and efficiency, positioning AnyScan® TRIO SPECT/CT to the best choice for your high-quality, high-throughput and ultra-fast imaging. Introduces highly accurate quantitative SPECT imaging into your daily NM workflow. Perform more 3D imaging, reduce radiotracer pharmacon cost, radiation exposure of the patient and your colleagues, improve patient comfort while achieving higher diagnostic confidence due to excellent image quality.

Jellemzők és előnyök

Ultra-fast SPECT/CT Scanning

  • The third detector and redesigned LEHR-HS collimator not even improve image quality, but also save time 
  • Seamless data acquisition with continuous SPECT/CT
  • PET-like workflow increases diagnostic confidence with total-body SPECT/CT 
  • Total-Body SPECT scan in 10-20 minutes 
  • Myocardial examination under 4 minutes

Transformable™ Gantry

Three different imaging modes:  

  • Ultra-fast total-body SPECT/CT with 120°detector position for PET like imaging  
  • Dual-head, 90° position for cardiac SPECT/CT
  • True planar imaging in 180° detector position

Optimized Time-Quality-Dose

  • Decrease Acquisition Time: The average acquisition time can be reduced to a quarter. A total-body bone SPECT scan can be implemented in 10 - 20 minutes. The shorter acquisition time helps to improve patient comfort and decrease the chance of motion artefacts. 
  • Maximize Image Quality: Improve diagnostic accuracy and confidence. Significantly higher system resolution and better contrast to noise ratio become available compared to the conventional two detector head SPECT systems. 
  • Reduce Administered Activity: Minimize patient dose and reduce the exposure of the administrator. The smaller amount of applied tracers can dynamically reduce the average radiotracer cost. 

Diagnostic Dual-Performance CT

  • 16 slice diagnostic CT with 32-slice reconstruction
  • Standard Low Dose protocols for diagnostic CT applications
  • Ultra-Low Dose CT with sub-mSv effective dose for attenuation correction and localization
  • Iterative Image Reconstruction with Tera-Tomo™ 3D CT
  • High power CT with up to 440 mA in diagnostic mode, 0.5 sec rotation speed, and 0.625 mm resolution, with on-the-fly dose modulation, Metal Artefact Reduction and Motion Artefact Correction.

Absolute Quantitative Imaging with Tera-Tomo™ 3D SPECT-Q Reconstruction

  • Mediso developed Tera-Tomo™ 3D SPECT-Q engine ensures quantitative results with precise SUV values 
  • Best image quality and quantitative results
  • Monte Carlo simulation based iterative SPECT/CT reconstruction
  • SUV calculation for radioisotopes. Not only for commonly used tracers like 99mTc, 131I, 123I, 177Lu, but for many more demanding theranostic isotopes
  • Available Normal Databases and possibility to create with easy workflow

Multi-FOV SPECT

  • Total-Body SPECT at extreme fast scan time, meaning instead of conventional 2D WB imaging, we can achieve 3D WB SPECT scan during similar acquisition time 
  • Alternating acquisition scan option. Detector head collect data in clockwise and counter-clockwise mode as well
  • Continuous gantry rotation makes the examination faster
  • Automatic stitching of acquired images

Highlighted Features for Smooth NM Workflow

  • NM localizer: This function combines the patient positioning procedure with whole-body planar acquisition to generate data for acquisition planning as an alternative to CT localizer
  • NM localizer AI: Artificial Intelligence supported image filter for planar bone scans is available in Nucline acquisition software. AI-filter is aimed to increase the image quality
  • List-mode data acquisition for retrospective image reconstructions and protocol optimization    
  • Real-time time-activity curve (TAC) display
  • NM-GO function: a foot switch was added to support smooth workflow, e.g. simultaneous administration of radiotracer and acquisition start

Alkalmazások

Képek

Hogyan segíthetünk Önnek?

További termékinformációkért, vagy támogatásért keresse szakértőinket!

Vegye fel a kapcsolatot