Features & Benefits
Flexible detector configurations
- 180°, 102° or 90° relative angle detector positions
- 540° gantry rotation
- Acquisition in PA and AP positions with standing patient at the same time
- Examination of patient sitting on wheelchair or sitting on a chair between the detectors or on the side with the detector surface pointing to the outside
- Acquisition on gurney in supine and semi-supine position
- Cardiac acquisition with online body-contouring
Wide selection of collimators
- Mediso offers the widest selection of collimator types in the industry
- Large number of low energy collimators providing highest sensitivity or highest resolution
- Best trade-off performance between resolution and sensitivity
Half-time / Half-dose imaging
Applied Tera-Tomo™ 2D and 3D image reconstruction offers activity reduction for your clinic while maintaining similar image quality. Depending on the clinician local preference, shorter acquisition time, or much reduced injected dose is possible with our Tera-Tomo™ engine.
Outstanding NEMA specification
- HP (High Performance) and UHP (Ultra High Performance) detectors guarantee high resolution SPECT images with industry standard NEMA measurements
- Next to the excellent intrinsic parameters, best system performance is ensured
- The correct choice of the collimator ensures the best trade-off between sensitivity and resolution.
Intuitive Acquisition System
- The Nucline™ acquisition software ensures intuitive and fast image acquisition workflow in the everyday routine environment
- Protocols may be customized while Nucline™ offers default solutions
- Pre-defined factory settings for all NM examination types
- User interface available from touchscreen and from control room
- User friendly software
- Unlimited options of advanced functions to customize your system
- Parallel workflow during patient scan
Fast collimator exchange
- Software guided, fast dual collimator exchange method in a space saving upright position
- Simultaneous exchange of both collimators, same sequence for all collimator types - even for High Energy
- Easy steps for the operator, guided from the Nucline™ acquisition software.
Applications
Publications
Images
Specification
Standard 9.5 mm, 5/8"
75 cm
up to 500 kcps
up to 245 cm (with extension)
54.5 x 40 cm
40 - 960 keV
Parallel hole from low- to high energy, Pinhole type
Nucline™ with all protocol sets
InterView™ XP
InterView™ FUSION
INVIA's 4DM for SPECT, Emory Cardiac Toolbox, or Cedars Sinai modules